System Performs Range Of Conducted Immunity Tests

The model CI00401 RF Conducted Immunity system is a complete self-contained measurement system designed to provide complete RF conducted immunity testing for automobile per a wide range of standards, including ISO 11452-4, GMW 3097, ES-XW7T-1A278-AC, DC-H224, BMW GS95002, and other automotive conducted immunity standards. The system performs tests at maximum power of 100 W (nominal) from 10 kHz to 400 MHz.

Article Tools

The test system consists of a signal generator, a three-channel power meter, a solid-state 100-W output-power amplifier ranging from 10 kHz to 400 MHz, a directional coupler, and control/test software. The complete system is contained in a single housing to simplify setup. The test system is ideal for use by both automotive test laboratories and by automotive equipment manufacturers. In addition to performing RF conducted immunity tests, the system's signal generator and RF power amplifier can be used independently. If special needs arise or when standards change, a larger amplifier can be connected to the system. Spectrum analyzers and monitoring equipment can also be controlled by the system software.

AR RF Microwave Instrumentation (www.arww-rfmicro.com)